My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3.9. SR 04-18-2005
ElkRiver
>
City Government
>
City Council
>
Council Agenda Packets
>
2000 - 2010
>
2005
>
04/18/2005
>
3.9. SR 04-18-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2008 8:34:47 AM
Creation date
4/14/2005 3:57:15 PM
Metadata
Fields
Template:
City Government
type
SR
date
4/18/2005
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />, . <br /> <br />24. Gymnasium 3 courts <br />25. Gymnasium 3 courts <br />26. Spill and Glare Control System <br /> <br />75 <br /> <br />50 <br /> <br />III. Light Loss Factor <br />The light loss factor used to determine the target light levels shall be a <br />maintenance factor of .8 multiplied by the lamp tilt factor. Maintenance <br />factor is calculated as follows: ambient temperature factor (1) x voltage <br />factor (1) x ballast factor (1) x lamp lumen depreciation (.84) x luminaire dirt <br />depreciation (.95) per I.E.S. Manual RP-6-88, p. 92. <br /> <br />IV. Uniformities <br />The uniformities of the playing field shall be measured by comparing the <br />maximum reading to the minimum reading. The ratio shall not exceed the <br />following: <br /> <br />Area of Lighting <br />Infield BasebalVSoftball Only <br />Main Area or Outfield BasebalVSoftball <br /> <br />Maximum to Minimum <br /> <br />2.0:1 <br />3.0:1 <br /> <br />V. Weight Reduction on the Crossarm <br />To prevent crossarms from sagging resulting in potential fixture <br />misalignment, the ballasts shall be mounted in an electrical component <br />enclosure on the pole separate from the fixture mounting. <br /> <br />VI. Structural Strength <br />To prevent misalignment of any luminaires or damage to the crossarms or <br />its components, the crossarm, reflector, and its attachment to the pole shall <br />be able to structurally withstand winds of 125 mph with a 1.3 gust factor. <br />Luminaires shall be attached to the crossarm by a minimum of two bolts, <br />which shall be stainless steel and Empigard coated. There shall be no <br />penetrations of the top or sides of the crossarms. <br /> <br />VII. Mounting Heights <br />To ensure proper aiming angles for reduced glare and to provide better <br />playability, the pole mounting heights from the playing field surface shall be <br />as specified on menu. <br /> <br />'Ij <br />I '~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.