Laserfiche WebLink
<br />Masxun Furniture/CU 04-39 <br />January 18,2005 <br /> <br />Page 3 <br /> <br />C. Preliminary Utility Plan <br /> <br />. The site will receive sanitary sewer and water service from Industrial Circle to the <br />south. There is an existing 6" water and sewer stub, which will be extended to the <br />building. Currently, the site shows no internal hydrants. A separate review memo <br />from Fire Chief Bruce West indicates an internal hydrant is required near the <br />northeast corner of the building. <br /> <br />. There is proposed storm sewer construction to take place on the site exiting into the <br />newly arranged storm water pond. All of the end sections should include trash <br />guards. <br /> <br />. Development of the site will require construction of a new driveway off 179th <br />Avenue and two new driveway access points off of Industrial Circle. In addition, <br />there are two existing driveway accesses constructed off of Industrial Circle, which <br />will need to be closed. The closing of these will require the removal of the radii and <br />the continuation of B618 concrete curb and gutter through the driveway opening. <br />The newly constructed driveways will require valley gutters if the existing grades are <br />not appropriate to continue drainage flow through the driveway openings. <br /> <br />If you have any questions regarding any of these comments, please call. <br /> <br />Sincerely, <br /> <br /> <br />TS!!L~ <br /> <br />City Engineer <br /> <br />S:\PLANNING\Case Files\2004\CU 04-39 Maxsun Fumirure\1-18-0S Engineer's memo.doc <br />