My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7.2 HRSR 07-10-2017
ElkRiver
>
City Government
>
Boards and Commissions
>
Housing & Redevelopment Authority
>
HRA Packets
>
2010-2019
>
2017
>
07-10-2017 SPECIAL
>
7.2 HRSR 07-10-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2017 9:23:50 AM
Creation date
7/7/2017 9:16:15 AM
Metadata
Fields
Template:
City Government
type
HRSR
date
7/10/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Beaudry Redevelopment TIF District #24 <br />Building Code, Condition Deficiency and Context Analysis Report <br />June 2, 2017 <br />Parcel No. & Building Name: <br />Address: <br />Parcel ID: <br />Inspection Date(s) & Time(s) <br />Inspection Type: <br />Summary of Deficiencies: <br />Estimated Replacement Cost: <br />B Residence <br />634 Quinn Ave NW Elk River, MN 55330 <br />75- 403 -0020 <br />May 5, 2017 11:55 am <br />Interior and Exterior <br />It is our professional opinion that this building is Substandard <br />because: <br />- Substantial renovation is required to correct Conditions found. <br />- Building Code deficiencies total more than 15% of <br />replacement cost, NOT including energy code deficiencies. <br />Estimated Cost to Correct Building Code Deficiencies: <br />Percentage of Replacement Cost for Building Code Deficiencies: <br />Defects in Structural Elements <br />$117,526 <br />$19,031 <br />16.2% <br />1. Roof is showing a protrusion mid -roof running from ridge to entryway addition indicating structure <br />settlement or heaving. <br />2. NW corner of house is not sitting tight to foundation wall indicating structural movement of <br />house /foundation wall. <br />3. Temporary basement floor jacks have been installed to stabilize 1St floor, indicating structural <br />deficiency in flooring system. <br />Combination of Deficiencies <br />1. Essential Utilities and Facilities <br />a. Portions of electrical wiring in basement is improperly installed and needs to be rerouted. <br />b. Circuit breaker box has open slots that need to be filled. <br />c. House lacks code - required AFCI receptacles in living room, bedrooms and hallways. <br />d. Current forced -air system does not meet current heating and ventilation code and needs to <br />be replaced. <br />e. Areas of basement plumbing was not installed per current plumbing code and needs to be <br />modified. <br />£ Basement utility sink faucet with hose thread does not have code - required vacuum breaker. <br />2. Light and Ventilation <br />a. None <br />Beaudry Redevelopment TIF District #24 Page 1 of 3 Building Report <br />LHB Project No. 170323 Parcel B, Residence <br />
The URL can be used to link to this page
Your browser does not support the video tag.