Laserfiche WebLink
5. All parking areas must be bound by B612 curb and gutter. Please amend the site plan to <br /> reflect the requirement. <br /> 6. A maintenance agreement for the permeable parking area will be drafted as part of the PUD <br /> agreement to ensure long-term functioning of the stormwater feature. <br /> 7. A land swap agreement between the City of Elk River and Modern Construction will be <br /> drafted as part of the approval process. <br /> Engineering <br /> 8. Little detail has been provided relating to the street and utility extension being proposed. <br /> There is no project included in the city Capital Improvement Plan to design or construct this <br /> utility and street extension as a public project. Authorization to construct the street will need <br /> to be authorized by the City Council. <br /> 9. 170`h Avenue will need to connect to the new Yale Street alignment. This shall be shown in <br /> all drawings. Proposed alignment of 170`h Avenue is attached. <br /> 10. Grades leading down to the underground parking area shall not begin decent until beyond <br /> the limits of the right-of-way and proposed sidewalk. <br /> 11. Drawings depict street parking outside of anticipated right-of-way on the east side of <br /> proposed Yale Street. Please amend drawings to reflect location of the street within the <br /> identified right-of-way. Street parking will be within the limits of the future street. <br /> 12. Proposed parking area north of new building is shown on adjacent private property. <br /> Acquisition of the private property will need to occur prior to recording the PUD <br /> agreement. <br /> Stormwater <br /> 13. Stormwater management requirements are needed as listed in Ordinance Sec. 78-503. - <br /> Stormwater and urban runoff control and Sec. 78-504. - Post construction stormwater <br /> management. NPDES permit is needed for construction activity disturbing one acre or <br /> more of soil.Also,a MIDS water quality report and soil borings showing the ground water <br /> depth is needed. Three feet of separation between the bottom of any proposed stormwater <br /> basin and ground water is required. <br /> 14. In the city approved feasibility report for Yale Street—Street and Utility Improvements <br /> (July 28, 2014) identifies a need to extend the existing stormwater pond south to <br /> accommodate runoff from the Yale Street extension. The current stormwater pond treats <br /> runoff from the city streets between 173`d Street and the south end of Yale Court. The city's <br /> ability to expand the existing pond must be maintained,and deviation from the 2014 plan <br /> will need authorization from the City Council. <br /> Fire Department <br /> 15. Fire department access has not been satisfied with the initial plan. Section 503 of the MN <br /> State Fire Code states that an access road shall be provided for all buildings. <br />