My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6.8. SR 07-17-2000
ElkRiver
>
City Government
>
City Council
>
Council Agenda Packets
>
2000 - 2010
>
2000
>
07/17/2000
>
6.8. SR 07-17-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2008 8:33:49 AM
Creation date
6/25/2004 8:33:27 PM
Metadata
Fields
Template:
City Government
type
SR
date
7/17/2000
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. McPherson <br />June 19, 2000 <br />Page 2 <br /> <br />Preliminary Grading Plan <br />1. Lot I Block 1 has relatively steep access off 173rd Avenue, is only one acre in <br /> size, and a portion of the southeast corner of the lot is occupied by an existing <br /> gas line easement. We question whether or not this lot is buildable. <br />2. In the Phase I condition, a large retention pond is proposed to hold the storm <br /> water runoff. This pond has no outlet and will operate through infiltration. No <br /> drainage calculations have been provided at this time. The side slopes on this <br /> pond must be 4:1 or flatter or the pond needs to be fenced. <br /> <br />o <br /> <br />In the Ultimate scenario, the pond is reduced substantially in size and an outlet is <br />shown under the railroad tracks to the City ditch on the east side of the tracks. It <br />is acceptable to provide an outlet under the tracks; however, a pond must be <br />provided prior to outletting that handles both the sediment control for the entire <br />area plus restricts the discharge under the railroad tracks to the pre-existing <br />conditions for the property. The City ditch on the east side of the railroad tracks <br />flows ultimately to a large pond constructed with the East Elk River <br />improvements. This pond has not been sized to accept unrestricted flow from <br />the K&L Addition. Storm drainage calculations will be needed also for the <br />Ultimate condition. We would recommend that these calculations be done with <br />Phase I so an adequately-sized area can be set aside for ponding in the future. <br />An emergency overflow location and elevation should be shown near the catch <br />basins in Vance Street, such that in a case where the catch basins are plugged, <br />water will overtop the curb and flow into the pond. <br />The typical street section on the preliminary grading plan should have B618 <br />concrete curb and gutter instead of B612. The bituminous base course should <br />be two inches in thickness rather than an inch and a half. <br />In most other commercial/industrial areas, concrete sidewalk is a part of the <br />street section. We question whether or not concrete sidewalk should be included <br />in this addition. <br /> <br />Preliminary utility plan <br />1. The Phase I preliminary utility plan shows water main looped through from 173rd <br /> Avenue to the frontage of road of TH 10. Easement will be needed for this <br /> looping outside of the proposed Phase I plat. The water main should be a <br /> minimum eight inches in diameter with six-inch pipe used for hydrant leads. <br />2. Hydrant spacing in commercial/industrial areas is required to not exceed three <br /> hundred feet. There will be additional hydrants needed to maintain this three <br /> hundred-foot maximum spacing. <br />3. The sanitary sewer is shown in the Phase I preliminary plat to be extended from <br /> 173r~ Avenue up Vance Street just beyond the plat boundary. In the Ultimate <br /> scenario it continues around Vance Street to the TH 10 frontage road. In the <br /> Phase I scenario, sanitary sewer should be added to provide service to Lot 3 <br /> Block 2. In the Ultimate scenario, sanitary sewer needs to be added to provide <br /> service to Lots 12 and 13, Block 1. <br /> <br />O:\PROJ\809020J\Ltr-061900-McPherson.doc <br /> <br /> Howard R, Green Company <br /> CONSULTING ENGINEERS <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.