Laserfiche WebLink
V.Mechanical and Electrical Requirements <br /> Conditions: <br /> A.Heating Facilities <br /> • Facilities Required: Two forced air furnaces in basement,antiquated,but in working order. <br /> Residential Occ: N/A <br /> Heat Supply: OK,to all areas. <br /> Occupiable Work Spaces: Ok,to all areas. <br /> B.Mechanical Equipment <br /> Mechanical Appliances: Antiquated,not efficient,gas-fired. <br /> Combustible Byproduct Removal: OK <br /> Clearances: OK <br /> Safety Controls: OK <br /> Combustion Air: Not found <br /> Energy Conservation: Not effiicent,should be replaced. <br /> C.Electrical Facilities <br /> Facilities Required: OK <br /> Service: Size seemed appropriate for building size,but older equipment. <br /> Electrical System Hazards: Access to service through mechanical equipment.Ground fault missing in wet areas. <br /> D.Electrical Equipment <br /> Installation: Appeared safely installed,but old.Not sure grounding and sizes of circuits are adequate for today's use. <br /> Receptacles: Ground fault missing in wet areas. <br /> Lights: Basement corridor lights inadeequate in style,lumens and quantity. <br /> E.Elevators N/A <br /> F.Ducts OK <br /> G.Other: <br /> V.Mechanical and Electrical Requirements <br /> Codes: <br /> A.Mechanical: Mechanical equipment not in fire-rated room(1 hour)separated for other areas.Equipment would not meet current codes. <br /> B.Electrical: Access is through mechanical equipment.Equipment wouldn't meet current codes: <br /> • C.Other: <br /> VI.Fire Safety Requirements <br /> Conditions: <br /> A.Means of Egress Building Entry(ies): Two exits required.Two exits to 1st floor but not accessible.Basement has only one exit. <br /> Aisles/Corridors: Basement corridor too long and narow. <br /> Locked Doors: Entry/exit doors do not have panic hardware,just deadbolt and closer. <br /> Emergency Escape: No emergency escape required or present. <br /> Stairs: Only one stair open to both floors and split entry. <br /> B.Fire Resistance Ratings <br /> Rated Assemblies: Doors into stair and basement corridor not rated.Doors into stair landigns not rated. <br /> Corridors: Basement has true corridor.Stasir landings at entry and upper floor have short corrdiors <br /> too. <br /> Exitways/Stairs: Non-rated open stair. <br /> C.Fire Protection Systems <br /> Smoke Detectors: Some,but not all areas.None in mechanical area. <br /> Alarms: None. <br /> Sprinklers: <br /> None.Basement would be required since opening and distance requirements exceeded. <br /> D.Other: Mechanical room is not separated from remainder of basement.Open to end of corridor. <br /> • <br /> 17 <br />