Laserfiche WebLink
I <br /> I <br /> • Report on Building Condition <br /> IBuilding ID/Business Name/Address: Law Office/Haberdashery 55-1 <br /> Satisfies Conditions Test for Structurally Substandard Building: Y <br /> ISatisfies Code Test for Structurally Substandard Building: Y <br /> Structurally Substandard Building(Y/N): Y <br /> IConditions Test <br /> I Under the tax increment law,specifically,Minnesota Statutes,Section 469.174,Subdivision 10,a building <br /> is structurally substandard if it contains"defects in structural elements or a combination of deficiencies <br /> in essential utilities and facilities,light and ventilation,fire protection including adequate egress,layout and <br /> condition of interior partitions,or similar factors,which defects or deficiencies are of sufficient total <br /> Isignificance to justify substantial renovation or clearance." <br /> The above building,based upon actual interior and exterior inspection and review of building permit <br /> I records,exhibits the following deficiencies that in our professional opinion contribute to justifying <br /> substantial renovation or clearance: <br /> I Structural Elements <br /> • Defects in building shell:step cracking present at various locations on interior walls near <br /> north side due to displacement of front façade(front doors out of plumb and do not close <br /> properly),east wall contains many active settlement cracks(attempted repairs/caulking not <br /> successful);south wall contains cracked masonry header over window due to building <br /> movement;roof parapet cap(concrete masonry unit)deteriorating at south east caner <br /> Essential Utilities&Facilities <br /> • Deficient in facilities for disabled:lack of designated disability parking available;lack of <br /> accessible hardware at interior doors;lack of maneuvering clearance and accessible features <br /> at toilet rooms;lack of accessible features at employee break room area;inaccessible service <br /> counter(height) <br /> I • Toilet fixtures lack adjacent non-absorbent floor and wall surfaces <br /> Light&Ventilation <br /> • Deficient in meeting Mechanical code: for building construction prior to 1989,mechanical <br /> systems do not provide sufficient number of air exchanges <br /> I Fire Protection/Egress <br /> • Deficient exterior door: deficient threshold height <br /> • Deficient interior stairway: insufficient stair clear width;deficient rise/run;insufficient stair <br /> I headroom clearance;deficient handrail height and extensions <br /> Similar Factors <br /> • Floor in Haberdashery deflects noticeably under normal weight—two locations <br /> Code Test <br /> I Notwithstanding the foregoing,the tax increment law also provides that a building may not be considered <br /> structurally substandard if it is in compliance with the building code applicable to new buildings or could <br /> be modified to satisfy the current building code at a cost of less than 15%of the cost of constructing a new <br /> I building of the same square footage and type on the same site. <br /> Estimated cost of new building of same size and type(Total Replacement Cost): $280,551.61 <br /> Estimated cost of correction of code deficiencies(Total Deficiency Cost): $43,018.56 <br /> IPercentage of Code Deficiency to Replacement Cost: 15.33% <br /> • Refer to Individual Building Summary Report for documentation of specific code deficiencies. <br /> I <br /> I <br />