Laserfiche WebLink
' Report on Building Condition <br /> • Building ID/Business Name/Address: Cinema Office Building 52-1 <br /> ' Satisfies Conditions Test for Structurally Substandard Building: Y <br /> Satisfies Code Test for Structurally Substandard Building: N <br /> ' Structurally Substandard Building(Y/N): <br /> Conditions Test <br /> ' Under the tax increment law,specifically,Minnesota Statutes,Section 469.174,Subdivision 10,a building <br /> is structurally substandard if it contains"defects in structural elements or a combination of deficiencies <br /> in essential utilities and facilities,light and ventilation,fire protection including adequate egress,layout and <br /> condition of interior partitions,or similar factors,which defects or deficiencies are of sufficient total <br /> ' significance to justify substantial renovation or clearance." <br /> The above building,based upon actual interior and exterior inspection and review of building permit <br /> records,exhibits the following deficiencies that in our professional opinion contribute to justifying <br /> ' substantial renovation or clearance: <br /> Structural Elements <br /> • Defects in exterior building shell:portions of parapet block wall on east wall are missing, <br /> deteriorated,or spalling-off;large step-crack present from exit door to parapet at mid-point of <br /> east wall <br /> Essential Utilities&Facilities <br /> ' • Deficient in facilities for disabled:lack of designated disability parking available;lack of <br /> maneuvering clearance and accessible hardware at interior doors;deficient ramp construction <br /> —additional handrails required;lack of maneuvering clearance and accessible features at toilet <br /> rooms;lack of accessible features for employee break room area;inaccessible drinking <br /> fountain(knee clearance) <br /> • Installation of elevator required for upper and lower levels due to building occupancy <br /> • Toilet fixtures lack adjacent non-absorbent wall and floor surfaces <br /> ' • Public conference room required to be on accessible route(ramp modification required) <br /> Light&Ventilation <br /> • Deficient in meeting Mechanical code: for building construction prior to 1989,mechanical <br /> ' systems do not provide sufficient number of air exchanges <br /> • Toilet room lacks means of natural or mechanical ventilation <br /> Fire Protection/Egress <br /> • Deficient exterior stairway: additional handrails required;deficient handrail height, <br /> ' terminations,and extensions;deficient guardrail construction <br /> • Deficient emergency egress: lack of bedroom emergency egress windows <br /> • Deficient exterior door: door does not swing in direction of travel <br /> ' • Deficient egress corridor construction:corridor exceeds maximum allowable dead-end length <br /> • Deficient interior stairway. insufficient stair clear width;deficient rise/run;insufficient stair <br /> landing area;stair flight exceeds allowable height for single run;insufficient stair headroom <br /> clearance;additional handrails required;deficient handrail height and extensions <br /> ' Code Test <br /> Notwithstanding the foregoing,the tax increment law also provides that a building may not be considered <br /> structurally substandard if it is in compliance with the building code applicable to new buildings or could <br /> ' be modified to satisfy the current building code at a cost of less than 15%of the cost of constructing a new <br /> building of the same square footage and type on the same site. <br /> Estimated cost of new building of same size and type(Total Replacement Cost): $1,492,289.35 <br /> ' Estimated cost of correction of code deficiencies(Total Deficiency Cost): $197,163.64 <br /> • Percentage of Code Deficiency to Replacement Cost: 13.21% <br /> Refer to Individual Building Summary Report for documentation of specific code deficiencies. <br />