Laserfiche WebLink
The private drive shown at the north end lines up with 8th Street directly across <br /> Jackson Avenue. Currently,the undeveloped property to the north owned by Rivers <br /> Christian Academy has a driveway access onto Jackson Avenue immediately north of <br /> the Jackson Street Villas site. Jackson Street Villas shows a combined access onto <br /> Jackson Avenue servicing both properties and lining up with 8th Street. <br /> • It is unclear whether the common area outside of the 76 building pads will all be <br /> encompassed with drainage and utility easements. If not, drainage and utility <br /> easements will need to be provided for the public sanitary sewer and water systems, <br /> along with the storm sewer and ponding areas. If the entire common area is to be <br /> deemed drainage and utility easement,this will accomplish the same thing. <br /> • Jackson Avenue is currently striped with two lanes; one north and one south, and <br /> two parking lanes, although the west side of Jackson Avenue adjacent to the Jackson <br /> Street Villas is currently signed "no parking". The requested rezoning to PUD and <br /> construction of 76 townhomes will provide significant traffic on Jackson Avenue <br /> wanting make left turns into the development. A left-turning vehicle will back traffic <br /> up with a one-lane roadway since it is illegal to pass a left-turning vehicle by using a <br /> striping parking lane. Therefore,we would recommend that the Jackson Street Villas <br /> project be required to pay$15,000 for the re-striping of Jackson Avenue to a three- <br /> lane configuration with a center left turn lane and no parking lanes. This will allow <br /> left-turning vehicles to get out of traffic and wait for a safe opportunity to make their <br /> left turn while still allowing through-traffic to move freely northbound on Jackson <br /> Avenue. <br /> B. Preliminary Grading Plan <br /> • The pond grading appears to be shown with 3:1 slopes. The City design standards <br /> require a maximum slope of 4:1, both above and below the water level of the pond. <br /> • The preliminary grading plan should include information such as invert elevations on <br /> the flared-end sections and rim elevations on the catch basins. <br /> • The site has very little open space or areas to plow snow from the streets. Where <br /> will snow in heavy snowfalls be stored? It should be made clear that it is not <br /> permitted to deposit excess snow in the wetland created at the northwest corner of <br /> the site. Snow may be stockpiled in the ponding area. <br /> • The following lots appear to have very flat driveways: 34, 43, 47, 48, 63, 66. <br /> • The following lots have rear yards that are flat or sloped towards the building: 9, 19, <br /> 15, 16. <br /> • The emergency overflow between Lot 51 and Lot 52 should be labeled in an <br /> elevation given. <br /> • Show existing spot elevations on the existing sidewalk and curb or bituminous to the <br /> east, south and north of the site to ensure that the grading fits with the surrounding <br /> property. <br /> • Since the streets are considered private, so will the storm sewer system along with <br /> the ponding area. <br /> S:\PLANNING\Case Files\2004\P 04-16 Jackson Ave Villas\10 5 04 Engineers memo.doc <br />