Laserfiche WebLink
ENERGY NOTES , <br />-Gontlnuoua air barrier at all <br />plumbing and heating penetrations. <br />-Piro stops must be Installed to block air <br />movement, <br />4Wtnd wash barrier required at the <br />exterior edge of attic Insulation. <br />Wind wash barrier required at <br />cantilevared floors and bay windows. <br />Window and door frames and <br />utility penetratlons must be sealed <br />Electrical boxes and fan housing <br />must be sealed to prevent air leakage. <br />The top of Interior partition walls must <br />be sealed to prevent air leakage. <br />Rim Joist must be sealed to prevent air leakage. <br />All exterior Joints that may be sources <br />of air Intrusion must be sealed, <br />Oetween wall Assemblies , rim Joist <br />and foundations must be sealed to prevent <br />air leakage. <br />toe / water protection <br />A min, of 2' -0" inside exterior <br />welt line a all eaves. <br />air barrel min I" air epee <br />2x6 treated sill plate <br />sill sealer <br />approved anchor$ a <br />I cop 6" block. <br />B eor a" block <br />r 10 stfo - Insulation <br />20 "x S' rooting <br />3/4" plywood I <br />Slued s nailed <br />3/4" furring s <br />Interior wails <br />roof vents, I per 300 sq. ft„ <br />50 It a roof peak, 90% a sorfl <br />II <br />II <br />II <br />II <br />II <br />II <br />provide wind crash sheathing <br />1 <br />it <br />11 <br />II <br />""M-44 Insulation II <br />II <br />4 mill poly v,b. <br />B /a" gypsum board 11 <br />II <br />T II <br />� II <br />II <br />\ n <br />It <br />trusses a 24" o.c. <br />2x6 sill plate <br />1/2" anchor bolts a 36" o.a <br />vertical reinforcemant 64 a 36" o.c. <br />3x4'* 0 16" o.c, <br />treated bottom plate <br />R -13 Insulation <br />4 mil poly v.Ef. <br />1/2" gypum board <br />I cor. B" curb block <br />II cor. a" block <br />hold block In I ", <br />I" rIS16 Insulation W/ <br />malting strips <br />NOTE, <br />house wrap <br />min. 3" bearing a ea. end <br />IN virryi stding <br />of all micro - Ism beams, <br />and headers w/ spans of <br />1'•D° or greater. <br />runless noted) <br />4 cor, 12" block irk <br />20 "xa" footing <br />NOTE, <br />provide solid bearinp under <br />DETAIL. <br />all beams, headers, girders <br />dean to foundation. <br />erg, roof trusses A 24" o.c. <br />1/2" csb sheathing <br />NOTE, <br />IY felt under 240 ib. asphalt shingles <br />size s mfg verify <br />oils s spacing or all trWsee/ <br />pact <br />---1` <br />Joist. <br />1/2" gypsum board <br />4 mll poly v.b. <br />r 19 Insulation x6 treated post <br />2x6 studs a 16" 0.0. Iaxlax40 base W/ atone <br />3/4" blidrite sheathing vsrwser <br />House wrap req. stone top <br />vinyl siding 12x12 custom post <br />�3 ml " 00"c"116 mat L <br />thermal break 6 poly <br />floor a block Install sub slab radon mitigation <br />system. <br />SECTION <br />scale 1/4" . 1' -0" page 4 of 4 contractor to verify all notes, <br />conditions, and dlmenslons, Ord <br />be responsible for the same. <br />