4.2.2.1. Screening <br /> Ten States Standards states that the capacity of the screens should meet the design peak <br /> instantaneous flow with one unit out of service. By these criteria the screening process is <br /> 2.08 MGD short in capacity for Design Option 2. Addition of a new screen would require <br /> an addition to the pretreatment building with substantial capital costs. Therefore, a <br /> manual screen insert would be constructed that could be placed in the existing channel if <br /> one of the screens was down for maintenance. The addition of the manual screen will <br /> meet the design requirements. <br /> 4.2.2.2. Flow Measurement <br /> The existing facility has 12-inch throat parshall flume for flow measurement with <br /> maximum capacity of 10.4 MGD. <br /> The existing parshall flume would meet the flow measurement needs for the Design <br /> Option No. 2. <br /> 4.2.2.3. Grit Removal <br /> The maximum capacity of the existing grit removal process of 7.0 MGD at PHWW flows <br /> is slightly less that the design PHWW flow of 7.27 MGD for Design Option No. 2. Due <br /> to the age and the capacity of the existing grit removal process, it is recommended that the <br /> City reevaluate the grit removal process when peak flows to the facility reach 90 percent <br /> of the capacity of the grit system. <br /> Addition of a grit cyclone to the grit classifier will also be investigated to alleviate <br /> plugging issues that have occurred with the existing classifier. <br /> 4.2.2.4. Primary Clarifiers <br /> To meet the PHWW flow of 7.27 MGD at the design year the existing facility would need <br /> an additional capacity of 4.23 MGD of capacity. Due to land area constraints the <br /> maximum clarifier area that can be added is two 40 foot diameter clarifiers as was <br /> discussed in Design Option No. 1. Two 40 foot diameter clarifiers would provide an <br /> additional 3.02 MGD of capacity at PHWW. However, this capacity could increase if <br /> City of Elk River—T12.104758 Page 21 <br /> Wastewater Treatment Facility Plan Prepared by Bolton&Menk,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.