Laserfiche WebLink
EXISTING PRECAST <br />CONCRETE WALL PANEL <br />SHEET METAL <br />REGLET INSERT WITH <br />REVERSE BEND <br />(SAW-mCUT REGLET <br />WITH POSITIVE <br />SLOPE) <br />FASTENERS 16"' O.C. <br />THROUGH NEOPRENE <br />WASHERS <br />COTTON ROPE WEEPS <br />MASTIC SEAL <br />18 GA. TERMINATION BAR <br />FASTENED 6" O.C. <br />SECURING EXISTING FULLY <br />ADHERED EPDM MEMBRANE <br />REMOVABLE KYNAR SHEET <br />METAL COUNTERFLASHING <br />WITH INTERLOCKING ENDS. <br />THROUGH-WALL FLASHING DETAIL <br />SCALE: NONE <br />SKYLINE BUiLDtNG ENVELOPE CONSULTANTS <br />15050 Cedar Ave S. Suite #116-333, Apple Yafiey, MN 55124 <br />(952}210-7803 <br />27 <br />