My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5.1. - 5.5. SR 02-009-1998
ElkRiver
>
City Government
>
City Council
>
Council Agenda Packets
>
1993 - 1999
>
1998
>
02/09/1998 - SPECIAL
>
5.1. - 5.5. SR 02-009-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2008 8:33:05 AM
Creation date
9/22/2003 9:04:37 PM
Metadata
Fields
Template:
City Government
type
SR
date
2/9/1998
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Memo to Board of AdjustmentsN97-21 <br />January 27, 1998 <br />Page 3 <br /> <br /> not exceed 25 percent of the tier area except 35 percent impervious <br /> surface coverage may be allowed in the first tier of general <br /> development lakes with an approved storm water management plan <br /> consistent with Part 904.08(3)." <br /> <br />As presented at the last meeting, Mike Trossen, the architect for Guardian <br />Angels, provided a development evaluation form (see attachment) which <br />outlined the amount of open space, building coverage, hard surface and total <br />impervious area. The 25 percent maximum impervious area does not apply <br />to tier I because this is the residential portion of the planned unit <br />development. The design criteria listed in this section of the Shoreland <br />Ordinance basically requires 50 percent open space be preserved as well as <br />meeting several other design criteria. On the other hand, tiers 2 and 3 are <br />considered commercial and are therefore required to maintain a maximum <br />impervious area of 25%. If tier I was also considered commercial, it too <br />would have to adhere to the 25% maximum impervious area. <br /> <br />As outlined on the development evaluation forms in tier 2 the amount of total <br />impervious area which includes building and parking areas, is 49%. In tier 3 <br />the total impervious area is 40%. As Guardian Angels architect Mike <br />Trossen presented to the Planning Commission at last month's meeting, <br />there is no way they can meet the maximum 25% impervious area unless <br />they reduced their plan by 50%. Therefore, the efforts made between the last <br />meeting and this meeting was to try to minimize the need for a variance. <br />One item the architect has taken a look at is reducing the footprint of the <br />commercial building and making it a three story building. The building <br />coverage area has decreased from 21,500 sq. ft. (22%) to 13,000 sq. ft. <br />(13.5%). However, the hard surface area or parking lot has increased from <br />16,597sq. ft. (17%) to 25,331 sq. ft. (26%). The bottom hne is the total <br />amount of impervious area has not decreased from the original proposal and <br />is still at 49% in tier 2 and 40% in tier 3. <br /> <br />Recommendation <br /> <br />Ao <br /> <br />The variance regarding the increase in density to allow 6 additional <br />assisted living units is a variance that could be avoided by eliminating <br />one townhouse unit and transferring that density to allow the assisted <br />living to have a total of 80 units without the need for a variance. <br />However, ff the assisted living building is constructed as proposed, the <br />footprint of the building could allow the additional six units to be <br />included within the footprint of the proposed building with no physical <br />change to the development. If the site plan proposed for the assisted <br />living is approved, staff would recommend approval of the variance <br /> <br />f:\shrdoc\planning\pc\v97-2 lx.doc <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.